In October, hot shower water may become lukewarm by November. This is often due to the winter weather rather than a malfunction. This is because the water entering the pipes becomes much colder in winter, forcing the water heater to work longer to produce water at the same temperature. However, there are still things to check. Here are five things to check for your water heater during the winter.
1. Set the temperature to 120°F (approx. 49°C).
First, check your thermostat settings. The U.S. Department of Energy recommends 120°F as a safe and appropriate temperature for most homes. Raising the temperature to 140°F can waste $36 to $61 annually due to heat loss into the atmosphere and increases the risk of burns. It is especially recommended to stick to 120°F in homes with children or the elderly.
2. Sediment Discharge — Flush once a year
Minerals in the water settle and accumulate at the bottom of the tank. This layer blocks heat transfer, causing hot water to heat up slowly and increasing gas and electricity consumption. If you hear thumping or boiling sounds while heating, it is a sign of sediment. Turn off the power or gas, wait for the tank to cool, then connect a hose to the bottom drain valve and drain the water until it becomes clear. The U.S. Department of Energy recommends draining one quart (approximately 1 liter) every three months. Please be careful, as the draining water is hot enough to cause burns.
3. Temperature and Pressure Safety Valve (T&P Valve) Test — Once a year
The T&P valve located at the top of the tank is a safety device that opens if the temperature or pressure rises excessively. Once a year, gently lift the lever to check if water is draining. If water does not come out or continues to leak, replacement is required.
4. Anode Load Check — Every 2–3 years
Inside the tank is an anode rod, a sacrificial metal rod that rusts itself to protect the steel tank from corrosion. If the rod wears down to the core, the tank itself begins to rust, significantly shortening its lifespan. It is recommended to check gas-powered tanks for the first time after about 3 years and electric tanks after 2 years, and then inspect them every 1 to 2 years thereafter.
5. Piping and Tank Insulation
Wrapping insulation around exposed hot water pipes leading from a water heater can reduce heat loss on the way to the shower. If the tank is located in an unheated space, tank insulation is also helpful, and the U.S. Department of Energy advises that tank insulation can save 7 to 16 percent of annual water heating costs.
When to call an expert
If rusty water comes out, water leaks from the bottom of the tank, or the pilot light on the gas water heater repeatedly goes out, a professional inspection is required. If you smell gas, do not turn on the stove; ventilate the area and contact the gas company or 911.
Water heaters are typically used for about 8 to 12 years. If you have them inspected before winter sets in, you can avoid the embarrassment of having lukewarm water on the coldest mornings.
source: HomeExpArts Winter Water Heater Guide, ASU in News Water Heater Inspection Notice for Winter, Mountain to Valley Home Inspections Water Heater Winter Preparation Guide |